48V 3.8kWh* Commercial Battery

48V 3.8kWh* Commercial Battery

Fixed Battery Pack - Fi3.8

  • Our Cell Module Assembly (CMA) units are packed and protected in a diecast aluminum casing for protection and durability.

  • A total solution that gives OEMs seamless integration and serviceable components, and gives operators always-ready, instant-on power for the tasks at hand.

  • Modular designs from expert partners, so you can confidently apply electrified power.

  • To learn more, download our literature here

Features

Durability

Aluminum Diecast enclosure for ultimate protection from wear and tear.

Increased Uptime

Designed for a life of up to 2,000 cycles with almost no scheduled maintenance needs. All major components are serviceable; components and modules can be replaced rather than having to replace the entire battery.

The Confidence You Want

Our Battery Management System is a dedicated technology, monitoring the pack's voltage and temperature to ensure safe and efficient operations.

Easy Integration

Dual CANbus communication protocol allows OEMs to communicate with the battery's J1939 (automotive standard) CANbus and use the second CANbus to communicate with the existing communication network without having to reprogram the legacy system.

Easy Troubleshooting

Via standard CANbus diagnostic protocols.

Warranty

Robust three year commercial limited warranty. CLICK HERE for details.

*Total energy measured using a 0.2C discharge per IEC 61960-3:2017

Specifications

At least one product must be displayed. Please select another option to remove this product

Fi Series Name
Fi3.8
Configuration
Lithium-Ion, 14S
Nominal Voltage (V)
51.6
Top Voltage (V) per IEC 61960
58.8
Top Voltage (V) for EV-Applications
58.1
Cutoff Voltage (V)
35.0
Nominal Capacity per IEC 61960
73.8 Ah / 3.80 kWh
Communication Protocols
J1939 (29-bit), CAN Open (11-bit)
Discharge Temperature Range
-20°C to +60°C
Storage Temperature Range (1 Month / 1 Year)
-20° to +60°C / -20°C to +25°C
Charging Temperature Range
-10°C to +60°C
Marketed Durability Hours/Cycles
2000 cycles to 80% initial capacity
Rated Charging Current (A)
37.5
Rate Discharging Current (A)
75
Parallel Capable
Yes, up to 10 batteries
Standard Charge Time
< 4.5 Hours
Vanguard Charger Output Power (W)
1050 W
On-Board or Stand Alone
Either

*Total energy measured using a 0.2C discharge per IEC 61960-3:2017