48V 5kWh* Commercial Battery

48V 5kWh* Commercial Battery

Fixed Battery Pack - Fi5.0

  • For maximum durability and protection, we have enclosed the Cell Module Assembly (CMA) units in a diecast casing.
  • For OEMs and operators, it's a total solution. OEMs get easy integration with their equipment and components that are serviceable. Operators get instant, reliable power for their jobs.
  • You can confidently apply battery power using modular designs that are engineered by experts.

Features

Expandable

Ability to add capacity ranges based on customer needs by connecting packs in parallel. For example, five 5kWh packs can be connected together for 25kWh of energy.

More Uptime

Minimal scheduled maintenance is required throughout the battery pack's long life of up to 2,000 cycles. All major components are serviceable, and it’s possible to replace individual sections, eliminating the need to replace the entire battery.

Safer Power

The Battery Management System (BMS) has features engineered to monitor the voltage and temperature of each CMA to make sure that it is operating within the nominal range for safety.

Easy Integration

OEMs can easily exchange information with the battery pack using its two CANbus ports. One CANbus uses the J1939 automotive standard, while the other is designed for uncomplicated data transfer with the OEM's current communication network: No reprogramming of that network is required.

Easy Troubleshooting

Via standard CANbus diagnostic protocols. The individual modules can be replaced and major components are serviceable.

8 Year Commercial Limited Warranty

Vanguard now offers an 8 year commercial limited warranty for all lithium-ion battery packs. CLICK HERE for more information.

Specifications

At least one product must be displayed. Please select another option to remove this product

Fi Series Name
Fi5.0
Configuration
Lithium-Ion, 14S
Nominal Voltage (V)
51.6
Top Voltage (V) per IEC 61960
58.8
Top Voltage for EV-Applications
58.1
Cutoff Voltage (V)
35.0
Nominal Capacity per IEC 61960
98.7 Ah / 5.0 kWh
Communication Protocols
J1939 (29-bit), CAN Open (11-bit)
Discharge Temperature Range
-20°C to +70°C
Charging Temperature Range
-10°C to +45°C
Marketed Durability Hours/Cycles
2000 cycles to 80% initial capacity
Parallel Capable
Yes, up to 10 batteries
Standard Charge Time
< 6 hours
Vanguard Charger Output Power (W)
1050 W
Battery Series
fixed
Rated Discharging Current
100