48V 3.8kWh* Commercial Battery

48V 3.8kWh* Commercial Battery

Fixed Battery Pack - Fi3.8

Seamless integration. One solution - multiple applications.

The Vanguard Commercial Battery with an integrated Battery Management System (BMS) is designed to power multiple commercial applications providing efficient power and performance. The CANbus-controlled Vanguard charger provides safe charging with the Vanguard special charge profile.

This is the next generation of integrated power. 

Features

Durability

Aluminium Diecast enclosure for ultimate protection from wear and tear.

Increased Uptime

Designed for a life of up to 2,000 cycles with no scheduled maintenance needs. All major components are serviceable and components and modules can be replaced rather than having to replace the entire battery.

Operational Confidence

The in-house designed Battery Management System monitors voltage and temperature throughout the pack and ensures the battery stays in efficient, safe operation.

Easy Integration

Two CANbus networks integrate with OEM legacy systems. The first is SAE J1939 standard, and the second is adaptable to customer requirements. A prequalified and plug-in ready charging system can be mounted on or off-board.

Easy Troubleshooting

Via standard CAN bus diagnostic protocols. The indivdual modules can be replaced and major components are serviceable. 

Global Warranty Coverage

Three year limited commercial warranty. See WARRANTY DETAILS.

Specifications

At least one product must be displayed. Please select another option to remove this product

Fi Series Name
Fi3.8
Configuration
Lithium-Ion, 14S
Nominal Voltage (V)
51.6
Top Voltage (V) per IEC 61960
58.8
Top Voltage for EV-Applications
58.1
Cutoff Voltage (V)
35.0
Nominal Capacity per IEC 61960
73.8 Ah / 3.80 kWh
Communication Protocols
J1939 (29-bit), CAN Open (11-bit)
Discharge Temperature Range
-30°C to +70°C
Charging Temperature Range
-10°C to +50°C
Marketed Durability Hours/Cycles
2000 cycles to 80% initial capacity
Parallel Capable
Yes, up to 10 batteries
Standard Charge Time
< 4.5
Vanguard Charger Output Power (W)
1050 W
On-Board or Stand Alone
Either
Rated Discharging Current
37.5

*Total energy measured using a 0.2C discharge per IEC 61960-3:2017

Lithium-Ion VS. Lead Acid Batteries