HOW DO I CHARGE A VANGUARD BATTERY TO MAXIMIZE ITS LIFE CYCLE?

- This FAQ article applies to all Vanguard battery packs -
Vanguard Commercial battery packs

> The 20-80% Charging Rule

Vanguard charger app

Batteries tend to have a longer lifespan and optimal performance when operated within a certain state of charge range. We recommend using Li-Ion batteries with a state of charge (SOC) of 20-80% of their capacity. Avoid discharging the battery below 10% and overcharging.

> Maximized battery lifespan

The "20-80 charging rule" for lithium-ion batteries suggests keeping the charge level between 20% and 80% of full capacity to maximize battery lifespan and efficiency. This means avoiding prolonged periods at 100% or near 0% charge.

> Minimized stress

Li-ion batteries experience more stress when fully charged or when completely discharged. Keeping the charge level in the middle range minimizes this stress, leading to less degradation and a longer lifespan

> Which charger is the right one for my battery?

Vanguard battery chargers, from 1050W to 3000W, are designed for Vanguard Battery Packs. They plug into standard outlets, can be combined for faster charging, and offer Bluetooth connectivity for app-based monitoring. Refer to the table below to determine the appropriate charger and the respective charging times.

 

 

  Vanguard 1425W Portable charger  

 

 Vanguard 1050W Charger

 

  Vanguard 1452W Charger  

 

  Vanguard 3000W Charger  

  48V 1,5kWh Swappable battery  

 

1,25 hours

  

 

N/A

 

N/A

 

  N/A  

48V 1,5kWh Fixed battery

 

N/A

 

N/A

 

 1,25 hours

 

  N/A  

  24V 3,5kWh Fixed battery  

 

N/A

 

6 hours

 

5 hours

 

4 hours

  48V 3,5kWh Fixed Battery  

 

N/A

 

4 hours

 

3 hours

 

2 hours

48V 5,0kWh Fixed Battery

 

N/A

 

 5,5 hours 

 

4 hours

 

 

2,5 hours

  48V 7,0kWh Fixed Battery tall  

 

N/A

 

8 hours

 

6 hours

 

3 hours

 48V 7,0kWh Fixed Battery long

 

N/A

 

8 hours

 

6 hours

 

3 hours

> What is the right temperature range for charging my battery?

For optimal safety, performance, and longevity, lithium-ion batteries require charging within a specific temperature range: 0°C to 45°C.

 

Risks of charging outside this range:

  • Low temperatures: Charging below 0°C can lead to lithium plating, which reduces battery capacity and poses safety risks like dendrite formation, potentially causing short circuits.

  • High temperatures: Charging above 45°C accelerates internal chemical degradation, shortening the battery's lifespan and increasing the risk of thermal runaway, fire, or explosion.

GET MORE BATTERY KNOWLEDGE

GET SUPPORT

Find a dealer icon

Take advantage of the expertise your local dealer can provide for service and support on your Vanguard engine.